Power Grid Security Guard: Conductor Sag Monitoring System
Contact Info
- Building C-9, Floor C, Precision达 Industrial Park, No.39 Qingfeng Avenue, Longgang Sub-district, Longgang District, Shenzhen City, 518116
- 李女士
- 13682351635
- 1920671927@qq.com
Core Technology:
The TLKS-PMG-HC device is not a simple monitoring device, but an "intelligent monitoring hub" integrating multiple cutting-edge technologies, building a complete closed loop of "data acquisition - trend prediction - abnormal response":
The device integrates high-precision sensors, real-time monitoring modules, intelligent early warning systems and remote communication technologies, and can capture subtle change data of conductor sag around the clock; relying on advanced algorithm models, it can accurately predict the future change trend of sag and identify potential risks in advance; when it monitors that the sag exceeds the safety threshold, it will immediately activate a multi-channel early warning mechanism, notify the operation and maintenance personnel to take countermeasures at the first time, nip the safety risks in the bud, and greatly reduce the incidence of line faults.
Core Functions:
1. It can sense and collect the minimum distance from the conductor to the ground, the angle between the tangent direction of the conductor at the clamp outlet and the horizontal direction, and the conductor sag, and transmit the measurement and calculation results to the condition monitoring agent or condition monitoring master station through the communication network;
2. It has an automatic acquisition function, which automatically collects the distance from the conductor to the ground, the angle between the tangent direction of the conductor at the clamp outlet and the horizontal direction, and the conductor sag at the set time interval. The minimum acquisition interval should be more than 5 minutes, the maximum acquisition interval should be less than 60 minutes, and the default time interval is 30 minutes;
3. It has a controlled acquisition function and can respond to remote instructions to collect data in real time;
4. It has the functions of collecting the voltage of the host battery and the probe battery.
5. It is equipped with a security chip, which can encrypt data and access the platforms of provincial companies.
Technical Parameters:
1. Power supply mode: Solar energy + high-performance battery
2. Communication mode: 3G/GPRS/CDMA/Ethernet
3. Operating voltage: DC12V
4. Operating current: 100mA
5. Battery capacity: 33Ah/12V
6. Solar energy: 18V/30W
7. Standby time: >10 days
8. Weight: 20Kg
9. Operating temperature range: -40℃~+85℃;
| Others | |